2 | DS7400Xi Series Addressable Control Panels
Eight Areas
Divide the control panel into eight separate system
areas, each area with its own keypads and reporting ID.
Keypads can be programmed as master keypads,
allowing access to all areas.
Flexible Digital Communication
The communicator works with most alarm receivers, and
supports 3/1, 4/1, 4/2, Contact ID, SIA, BFSK digital
communicator formats and pager format. The pager
format allows the control to dial a digital pager service
and leave a numeric message representing the account
number and event code.
Input and Output Cross Matrix
Input and output cross matrix allows output functions to
follow the status of specific input zones. Outputs can be
programmed to follow any combination of one or two
zones, open or closed, with the system armed or
disarmed.
LED and Alphanumeric Keypad Support
DS7445V2 LED Keypad: Provides an LED per zone
(LEDs 1-8 for main board zones and LEDs 9-16 for
expansion zones), and eight system status LEDs that
show conditions such as armed, fire alarm, and
trouble.
DS7445i LED Keypad: Provides an LED per zone (for
main board zones 1-8 only), and eight system status
LEDs that show conditions such as armed, fire alarm,
and trouble.
DS7447V2 Alphanumeric Keypad: Two line, freely
programmable display allows 16 characters of
custom text to be programmed for zone and area
descriptions. The user can adjust the sounder volume
and backlight intensity using easy two-button
commands. The DS7447V2 is required for system
programming.
Note: LED and LCD keypads may be mixed in the same
system.
Octal Relay Modules
The DS7400Xi Series Control Panels support up to two
DX3010 Octo-Output Expander Modules. Each module
supplies eight relay or solid state outputs to follow
system events or to follow programmed Output
Functions from the control panel.
Output Functions
Program the output functions to follow system events or
to follow one or two specific zones in a cross matrix (see
Input and Output Cross Matrix). Output functions can
control octal relay outputs or addressable bus outputs.
Programmable from Keypad or Remotely
The system is completely keypad programmable. No
need for expensive handheld programmers.
RPS-INTL provides remotely programming through an
IBM
®
PC (or IBM compatible) running a Microsoft
®
Windows
®
operating system and communicating
through a standard Hayes modem. Using an off-site
computer to run diagnostics, arm systems, and
bypass zones reduces service visits to a premise and
provides quick customer assistance.
Smoke Detector Alarm Verification
The DS7400Xi Series Control Panels can automatically
reset the smoke detectors following an alarm. If a
second alarm occurs within the verification window, an
immediate fire alarm occurs, reducing potential false
alarms while providing fast response to an alarm.
Two Independent Entry Delays
Program zones to select from one of the two entry delay
times. Users can select a longer entry delay time for
zones located a long distance from the keypad.
Certifications and Approvals
The DS7400Xi Series Control Panels comply with the
following certifications, standards, and approvals.
Belgium BEL
INCERT
Europe CE
Installation/Configuration Notes
Compatible Products
Category Product
Keypads DS7445Vi LED Keypad
DS7445V2 LED Keypad
DS7447E LCD Keypad
DS7447V2 LCD Keypad
Modules Conettix IP C900V2 Dialer Capture Module
C900TTL-E Dialer Capture Module
Conettix IP DX4020 Network Interface Module
Door Access Control Module (DACM)
DS7420i Dual Phone Line/Bell Supervision Module
DS7430 Multiplex Bus Driver Module
DS7432/E Eight-Input Remote Module
DS7433/E Eight-Input Direct Module
DS7436 Addressable Expansion Module
DS7457i/iF Single-Zone Input Module
DS7457iE Single-Zone Input Module
Vue de la page 1
1 2 3 4

Commentaires sur ces manuels

Pas de commentaire