Detection Systems DS7092 Spécifications Page 90

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 181
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 89
Figure 34.1. (Added) Special junction box.
f. Connect the dc leads of the ME-26A/U to
h. Insert the TS-1777/VRM-l test probe tip
terminals A (ground) and J (B+) of the 18- in test jack A. The GREEN indicator must light.
terminal female connector of the CX-7899/VRM-
1. The voltage must be between 21 and 22 volts
65. Output Tests
dc.
(fig. 34.4)
Note. For the remaining tests, l djust the model 3206
a. Leave the TS-1777/VRM-l ON-OFF switch
power supply form output between +23.4 and +28.6 volts
in the ON position, and the selector switch at A.
dc.
b. Adjust the output of the PP-3514/U to 0
g. Connect the AN/USM-98 positive lead to
volt dc.
TS-1777/VRM-l test jack A, and the negative
c. Through the special junction box, connect
lead to the probe ground connector. The voltage
the output of the PP-3514/U to the TS-1777/
indicated must be between 15.2 and 16.8 volts dc.
VRM-1 probe assembly, and connect the AN/
4
AGO 8834A
Vue de la page 89